Thermal systems
Steam Condenser: Thermal Design & CFD
Evaluated condenser configurations for a 105 MW heat-rejection requirement, comparing tube count and flow arrangement in ANSYS Fluent.
Team design challenge · GE Vernova
My contribution
I contributed to the GE Vernova team study, evaluating condenser concepts and comparing one- and two-tube, two-pass configurations at equal mass flow. The design work considered air versus water cooling, heat-transfer area, footprint, and pumping requirements.
Results & observations
Increasing tube count produced a predicted 32.6% heat-transfer improvement in the simplified CFD comparison. This supported the concept comparison; it did not establish the condensation performance of a full-scale 105 MW system.
A system-level choice
The challenge was to develop a condenser concept for a roughly 105 MW heat-rejection requirement. The study compared air and water cooling, then considered thermal surface area, footprint, pumping requirements, and a shell-and-tube arrangement.
Comparing configurations
Simplified ANSYS Fluent models compared materials, tube configurations, and baffle arrangements. The reported 32.6% heat-transfer difference applies to the modeled tube-count comparison at equal mass flow, not to a validated full-scale plant.
Beyond the contour plots
The analysis required defining fluid and metal domains, preparing a mesh, and revisiting inlet assumptions. The team also compared air and water cooling and developed a correlation-based capital-cost estimate. Those costs depend on assumed materials, dimensions, and correction factors; they are not supplier quotes.
Limits of the concept
The proposed full-scale design and the simplified CFD model are different levels of analysis. The simulation does not establish full-scale condensation performance. Fouling, vibration, water availability, and a validated phase-change model remain important follow-up work.
Tools & methods
- ANSYS Fluent
- Heat exchangers
- CFD comparison
- Thermal sizing
- Flow distribution
- Baffle arrangements
- Material selection
- Cooling-system tradeoffs